Description:
The PVDF Turbine Flow Sensor has been developed to perform a fast interchange of the flow tube to accommodate hygienic applications in the medical, pharmaceutical, and bio-technological industries. It has low flow capabilities and high resolution square wave output. The flow tube can be sterilized to 140°C (284°F) and is gamma radiation resistant up to 50 kGy. These features make this model ideal for monitoring and controlling fluid flows in hygienic applications.
The Turbine flow sensor contains a light-weight turbine with a ruby bearing. The turbine follows the fluctuation of flow accurately and IR detection of turbine rotation generates a high resolution digital output, All wetted parts are made of PVDF® and Ruby. The sensor is suitable for clear, opaque, corrosive and aggressive fluids. This unit meets all US Pharmacopeia Class VI requirements.
Specifications:
- Dimensions: 2.45in (62.3mm) L, 2.63in (67mm) H
- Flow range: 0.079-5.28 G/min (0.3 - 20 L/min)
- Accuracy: 1% of reading
- Repeatability: < 0.15 %
- Wetted parts: PVDF / Ruby
- Tube connection: 0.472in (12mm) Barb
- Liquid temperature in Deg °C: -20 to +80
- Max. pressure at 20° C in PSI/bar: 290/20
- Viscosity in cSt:. 0.8 – 10
- Number of Pulses/Litre (Water): 4,500
- Power supply: 5 - 30 Vdc
- Output signal: 5 - 30 V sq. wave
- Power consumption: 34 mA at 5 V
- Cable: 3 Conductor, PVC, 1 meter in length
- 1 year manufacturer's warranty
- FDA Approved
Manufacturer’s Part Number: 0085PHP01CA
Data Sheets:
These Units are Stock to 3 Week Lead-Time. For a Delivery Quote, call 978-768-6526 or email: sales@rndwarehouse.com